PENTAIR – Ecoline

Codeline 40E is membrane housing series of 4” diameter with end entry design. This is used for commercial and industrial RO applications. Vessel models are available in operating pressure of 300 PSI, 600 PSI and 1000 PSI. They are made up of epoxy/ glass composite to meet the demands of long term and continuous use in RO processes. Codeline 40E vessels can accommodate any standard 4” membrane element.

Features

  • Single piece head assembly manufactured by engineering thermoplastics provides high strength and superior chemical resistance
  • Improved head seal captured in the head gives better sealing, minimizing leakage probability
  • Integrally formed locking  grooves provide better locking strength
  • Mirror finish ID for easy and quick loading and unloading of membranes
  • Exteriors coated with high gloss polyurethane paint for UV resistance
  • Head seal area is formed by mandrel surface; hence more accurate
  • Compact design for use in compact and low energy water treatment units
  • Quick lock head retention system for quick onsite maintenance

eco-line-1
eco-line-2
eco-line-2

4 inches

Codeline 40E is membrane housing series of 4” diameter with end entry design. This is used for commercial and industrial RO applications. Vessel models are available in operating pressure of 300 PSI, 600 PSI and 1000 PSI. They are made up of epoxy/ glass composite to meet the demands of long term and continuous use in RO processes. Codeline 40E vessels can accommodate any standard 4” membrane element.

End Entry
Available Pressure rating 300 psi (40L Series)
Available Element Length 1 Element to 3 Element

SPECIFICATIONS

Codeline 40E30N

Codeline 40E60

Codeline 40E100

Drawing no. 518016 518017 518015
Design/ Max. operating pressure 300 PSI/ 20 bar 600 PSI/ 41 bar 1000 PSI/ 68 bar
Max. operating temperature 120°F/ 49°C 120°F/ 49°C 120°F/ 49°C
Qualification pressure 1800 PSI/124 Bar 3600 PSI/248 Bar 6000 PSI/413 Bar
Element length 1-3 1-6 1-7
Download adapter list Not applicable Adapter list 40E60 membrane housings Adapter list 40E100 membrane housings
Download datasheet Datasheet Codeline 40E series Datasheet Codeline 40E series Datasheet Codeline 40E series
Download drawing Codeline drawing 40E30N Codeline drawing 40E60 Codeline drawing 40E100

8 inches

Codeline 8 inch Ecoline is membrane housing series of 8” diameter with side entry design equipped with OCTA Technology. This is used for commercial, municipal and industrial RO applications. Vessel models are available in operating pressure of 300 PSI and 450 PSI. They are made up of epoxy/ glass composite to meet the demands of long term and continuous use in RO processes. This vessel can accommodate any standard 8” membrane element.

Side Entry
Available Pressure rating 300 & 450 psi (80-300 Series)
Available Element Length 1 Element to 8 Element

SPECIFICATIONS

Ecoline 80-300

Ecoline 80-450

Drawing no. 99196 99197
Design/ Max. operating pressure 300 PSI/20 Bar 450 PSI/31 Bar
Max. operating temperature 120°F/ 49°C 120°F/ 49°C
Qualification pressure 1200 PSI/82 Bar 1800 PSI/124 Bar
Element length 1-8 1-8
Download adapter list Adapter list 8 inch membrane housings Adapter list 8 inch membrane housings
Download datasheet Datasheet Ecoline 8 inch series Datasheet Ecoline 8 inch series
Download drawing Codeline Ecoline Drawing 80-300 Rev N Total Codeline Ecoline Drawing 80-450 Rev Q Total


PENTAIR – Aqualine

Features

  • High flow filtration with a wide range of cartridge micron rating to suit your application
  • High-performance pleated media filtration technology
  • Long lasting rugged FRP housings from Codeline, available in 150 & 300 psi pressure rating
  • ASME complaint FRP housings for critical applications
  • labour-saving quick module change
  • Can be installed both vertically and horizontally
Aqualine housing 80AQ15-60
Aqualine cartridge - example
150 PSI
80AQ15-60 (Non Coded)
80CF15-60 (Non Coded)

SPECIFICATIONS HOUSINGS

80AQ15-60 (Non coded)

80CF15-60 (Non coded)

80CF15-60 (Code Compliant)

80CF30-60 (Code Compliant)

Drawing number 200268 17028 17036 17038
Design/ Max. operating pressure 150 PSI/10 Bar 150 PSI/10 Bar 150 PSI/10 Bar 300 PSI/20 Bar
Max. operating temperature 113 °F /45 °C 140 °F /60 °C 140 °F /60 °C 140 °F /60 °C
Qualification pressure 900 PSI/62 Bar 900 PSI/62 Bar 900 PSI/62 Bar 1800 PSI/124 Bar
Element length 60″ 60″ 60″ 60″
Download drawing Drawing Aqualine 80AQ15-60 Drawing 80CF15-60 Non Coded Drawing 80CF15-60 Coded Drawing 80CF30-60 Code Compliant
Download datasheet Datasheet Aqualine 80AQ15-60 Non coded Datasheet Aqualine 80CF15 Non coded Datasheet Aqualine 80CF15 Code compliant Datasheet Aqualine 80CF30 Code compliant
300 PSI
80CF30-60 (Code Compliant)
80CF15-60 (Non Coded)

SPECIFICATIONS CARTRIDGES

ALN01-60B

ALN05-60B

ALN10-60B

ALN20-60B

Download datasheet Datasheet Aqualine ALN01-60B Datasheet Aqualine ALN05-60B Datasheet Aqualine ALN10-60B Datasheet Aqualine ALN20-60B